Usage

Data cables – shielded with inner sheath – suitable for measuring, control and regulation purposes with low power loads. Use in particular for voice lines in telecommunication systems, for impulse and data transfer and for electronic devices with plugged systems in small dimensions.

These shielded data cables have an inner sheath made from high-quality PVC designed to provide additional mechanical protection for the core wiring.

Cross-section area: 0.14 mm² to 0.5 mm²

Properties

Highest-quality copper litz, balanced core and sheath qualities and optimum construction features guarantees, even with high core numbers, a relatively low exterior diameter; first-class mechanical values and high flexibility.

Special versions with special conductor constructions, core identifiers, sheath colours, for special resistances and expanded temperature ranges are all available on request.

Technical data

Download datasheet
Conductor Temperature range
Litz fine copper wire, not insulated according to VDE 0295
class 5 / IEC 228 class 5 (smaller than 0.5 mm² based on)
In motion -5° C up to +70° C, still up to -30° C
Insulation Flame retardancy
PVC TI 1/2 according to VDE 0281 Part 1 IEC 332.1 or VDE 0482 Part 265-2-1
Core identifier Bending radius
Colour-coded according to DIN 47100 15 x D (cable diameter)
Stranding Conductor resistance
Concentric cores in layers, colour sequence, thus, alignment from outside to inside See Technical information
Inner sheath Test voltage
PVC according to VDE 0281 Part 1 Effective 2,000-3,000 Volts according to cross-section
Shielding Nominal voltage
Entire sheath made from tin-plate braided copper wire with an optical density of at least 80 % Maximum of 300 Volts
Sheath Breakdown voltage
PVC TM 1/2 according to VDE 0281 Part 1
Default colour, grey RAL 7001
Minimum 3,000 Volts
Norms Resilience up to 30° C
According to or based on
VDE 0245, 0281, 0295, 0472, 0473, 0482, 0800, 0812, 0814, 0817
See Technical information