Products / Data cables / MUNFLEX®-Data-CH

Usage

Data cables – shielded – suitable for measuring, control and regulation purposes with low power loads. The cables are free from PVC and completely free of halogen. Used in voice connections in telecommunication systems, for impulse and data transfer and for electronic devices with plugged systems in the smallest of dimensions, preferred in sectors with high density of people and anywhere where particular care for people and property is taken seriously.

This range is to be particularly recommended from the environmental protection point-of-view.

The cables have shielding braids made from tin-plated copper wires with a high optical density. This protects against internal or external electro-magnetic interference.

Cross-section area: 0.25 mm² to 0.5 mm²

Properties

The used materials only release low corrosive gases in the event of a fire. They have a low toxicity, low smoke density and are flame resistance in accordance with IEC 332.1, free of halogen and oil-resistance in accordance with IEC 811-2-1 (4 hours / 70° C).

Special versions with special conductor constructions, core identifiers, sheath colours, for special resistances and expanded temperature ranges are all available on request.

Technical data

Download datasheet
Conductor Low on smoke
Litz fine copper wire, not insulated according to VDE 0295
class 5 / IEC 228 class 5 (smaller than 0.5 mm² based on)
Light permeability > 80 %*
Insulation Oil resistance
Ethylene Copolymer HI2 according to VDE 0207 Part 23 According to IEC 811-2-1 (4 hours at 70° C IRM 902)
Core identifier Water absorption
Concentric cores in layers, colour sequence, thus, alignment from outside to inside According to IEC 811-1-3 (14 days at 70° C)
maximum of 0.4-1.3 mg/cm³*
Wrapping Dielectric constant
Polyester sheet 3.15*
Shielding Hardness
Entire sheath made from tin-plate braided copper wire with an optical density of at least 80 % Shore D 39-51*
Sheath LOI
Ethylene Copolymer HM2 according to VDE 0207 Part 24
Default colour, grey RAL 7001
Approximately 28-34*
Norms Bending radius
According to or based on
VDE 0207, 0245, 0295, 0472, 0473, 0482, 0800, 0812, 0814, 0817
10 x D (cable diameter)
Temperature range Conductor resistance
In motion -25° C up to +70° C, still up to -40° C See Technical information
Flame retardancy Test voltage
IEC 332.1 or VDE 0482 Part 265-2-1 Effective 2,000-3,000 Volts according to cross-section
Corrosiveness Nominal voltage
According to IEC 754-2 approximately 1.8 µS/m* Maximum of 300 Volts
Toxicity Breakdown voltage
According to NES 713 approximately 1.5* Minimum 3,000 Volts
Halogen content Resilience up to 30° C
According to IEC 754 < 0.1 %* See Technical information

The product conforms to the 2006/95/EU directive ("low voltage directive") CE.

*All information regarding the insulation and sheath materials has been supplied by the supplier and is communicated with no legal obligations.