Products / Control cables – for normed safety / H05V3V3H6-F

Usage

Control cables for lifts with large hub heights and high travel speeds.

Properties

These are cables for use under lifts both indoors and out. In the latter case, the cables should be protected from direct rain, snow and sunlight.

The cables are suitable for ambient temperatures of -15° C to +40° C. The maximum travel speed is 4.0 m/second and there is a maximum hanging height of 45 m.

In the event of larger hanging heights and greater travels speeds, the cables must be supplied with stress relief element based on the construction type above which will enable a travel speed of a maximum of 6.3 m/second and hanging heights of over 45 m.

In the event of special regional conditions, in particular, for example, lower ambient temperatures the upper limit for travel speed and acceleration may need to be reconsidered.

Technical data

Download datasheet
Conductor Flame retardancy
Litz fine copper wire, not insulated according to VDE 0295
class 5 / IEC 228 class 5
IEC 332.1 or VDE 0482 Part 265-2-1
Insulation Bending radius
PVC TI 4 according to VDE 0281 Part 1 10 x D (cable thickness)
Core identifier Conductor resistance
Black cores with white numbers, earth conductor green-yellow 0.75 mm² - max. 26.0 Ohm/km
1.00 mm² - max. 19.5 Ohm/km
Core arrangement Test voltage
cores are arranged in parallel and in groups of up 4 to 5 cores Effective 3,000 Volts
Sheath Nominal voltage
PVC TM 4 according to VDE 0281 Part 1
Default colour, black RAL 9005
Maximum of 500 Volts
Norms Breakdown voltage
According to or based on
VDE 0281, 0293, 0295, 0472, 0473, 0482
EN 50214
Minimum 6,000 Volts
Temperature range Resilience up to 30° C
In motion -15° C up to +70° C, still up to -30° C
In motion outdoors -15° C to +40° C (in  accordance with
EN 50214)
See Technical information

The product conforms to the 2006/95/EU directive ("low voltage directive") CE.